HPE FlexNetwork 5140 24G 4SFP+ HI Switch (R9L61A)
|
I/O ports and slots
|
24 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T) with 8 combo ports (RJ45 or SFP)
|
4 1/10G SFP+ ports, 1 port expansion module slot.
|
Attention: SFP PLUS can also support 1G SFP and 1G SFP-GE-T (only works at GE)
|
Additional ports and slots
|
1 dual-personality (RJ-45 or mini-USB) serial console port
1 RJ-45 out-of-band management port
1 USB 2.0
|
Power supplies
|
2 power supply slots 1 minimum power supply required
|
Fan tray
|
Airflow direction is from side to back
|
Physical characteristics
|
Dimensions
|
17.32(w) x 14.17(d) x 1.71(h) in.
(44.00 x 36.00 x 4.36 cm)
(1U height)
|
Weight
|
≤6.7 kg
|
Memory and processor
|
2 GB SDRAM; Packet buffer size: 4 MB, 512 MB flash
|
Mounting and enclosure
|
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)
|
Performance
|
1000 Mb Latency
|
< 5 µs
|
10 Gbps Latency
|
< 3 µs
|
Throughput
|
180 Mpps
|
Routing/Switching capacity
|
288 Gbps
|
Routing table size
|
8K
|
MAC address table size
|
32K
|
Environment
|
Operating temperature
|
23°F to 113°F (-5°C to 45°C)
|
Operating relative humidity
|
5% to 95%, noncondensing
|
Non-operating/Storage temperature
|
-40°F to 158°F (-40°C to 70°C)
|
Non-operating/Storage relative humidity
|
5% to 95%, noncondensing
|
Acoustic
|
low speed fan: 53.0 dB, High speed fan:
68.9 dB. ISO 7779
|
Electrical characteristics
|
Frequency
|
50/60 Hz
|
Maximum heat dissipation
|
ranges from 81.89 BTU/hr to 324 BTU/hr depending on power supply configuration
|
Current
|
6A
|
Voltage
|
100-240 VAC, rated (90-264 VAC, max)-48 to -60 VDC,
rated (-36 to -72 VDC, max) (depending on power supply chosen)
|
Maximum power rating
|
95 W (dual DC)
|
Idle power
|
29 W (dual AC)
|
Notes:
|
- Idle power is the actual power consumption of the device with no ports connected.
- Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated
|